Speci昀椀cations
Input type
DC voltage
DC current
≤ 300 VDCᜡ ≤ DC 2 A
Max. allowable
input
≈ 150 % F.S. for each measured input range
Display method 7-segment (red) LED (character height: 14 mm)
Display accuracy ± 0.2 % F.S. rdg ± 1-digit
Display scale
19999
Sampling time
2.5 times / sec
Response speed ≈ 2 sec (0 to 19999)
Sampling cycle
300 ms
Operation
Dual integral method
method
Unit weight
≈ 172 g
Approval
Power supply
100 - 240 VACᜠ ± 10 % 50 / 60 Hz
01)
Power
consumption
2 W
≥ 100 MΩ (500 VDCᜡ megger)
Insulation
resistance
2,000 VACᜠ 50 / 60 Hz for 1 min
Dielectric
strength
Noise immunity ± 1 the square wave noise (pulse width: 1 ㎲) by the noise simulator
0.75 mm double amplitude at frequency of 10 to 55 Hz (for 1 minute) in
each X, Y, Z direction for 1 hours
Vibration
0.5 mm double amplitude at frequency of 10 to 55 Hz (for 1 minute) in
Vibration
(malfunction)
each X, Y, Z direction for 10 min
300 m/s
(≈ 30 G) in each X, Y, Z direction for 3 times
2
Shock
100 m/s
(≈ 10 G) in each X, Y, Z direction for 3 times
Shock
(malfunction)
2
0 to 50 ℃, storage: -25 to 65 ℃ (no freezing or condensation)
Ambient
temperature
35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)
Ambient
humidity
01) Power supply 24 - 70 VDCᜡ option is also available to order.
Error
• When 19999 or -19999 昀氀ashes with a certain measurement input, disconnect power
supply and then check the cables.
Scaling
Rotation,
speed
Power
≤ 10 VDCᜡ
≤ 10 VDCᜡ
DC 4 - 20 mA
Connections of Applications
■ DC voltmeter connection
• V1 (measuring voltage): ≤ 300 VDCᜡ
Hi
Power
V1
Panel
supply
Load
meter
Low
■ DC ammeter connection
• I (measuring current): ≤ DC 2 A
Hi
Power
I
Panel
supply
meter
Low
Load
■ Simulaneous connection of voltmeter and ammeter
+
+
A
Load
power
-
HI
LOW
HI
Voltmeter
Ammeter
DC power
DC power
supply 1
supply 2
• A: Compared to measurement input range, higher measuring voltage needs a multiplier and
lower measuring voltage needs a shunts.
• Connect the separated power supply each.
• (-) terminal of the power and (-) terminal of measurement input are shorted.
In case of using same power supply, measurement error or overcurrent may occur.
■ Power meter connection
Power factor transducer
P.T
L1
L2 L3
P.T
Output
: 0 - 10 VDCᜡ
C.T
C.T
Load
■ Rotation / Speed meter connection
HI
LOW
Tacho generator (T.G)
Motor
• Tacho generator (T.G)
: This generator makes a voltage in proportion to revolution speed of motor. The panel
meter receives the voltage and displays the number of revolution.
■ Scaling meter connection
Temperature
Sensor
OUTPUT:
CONVERTER
DC 4 - 20 mA
Pressure
Sensor
18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002
www.autonics.com | +82-51-519-3232 | [email protected]
• V1 (measuring voltage): ≥ 300 VDCᜡ
Multiplier
R1
V1
V2
Panel
Load
R2
meter
Select R1 and R2 in order to make V2 less than max.
measuring voltage using multiplier.
(R1 > R2)
V2 =
× V1
R2
R1+R2
• I (measuring current): ≥ DC 2 A
Hi
I
Shunt
50 mVDCᜡ
Panel
meter
Low
Load
When the current is higher than DC 2 A, use shunt.
Second section of shunt is 50 mVDCᜡ.
-
Load
LOW
+
Hi
Power
Panel
supply
meter
Low
-
Power
Panel
supply
meter
+
Hi
Power
Panel
supply
meter
Low
-
Hi
Power
supply
Low
Power
supply