DYNAPAR HS35IQ Series Installatiehandleiding - Pagina 7
Blader online of download pdf Installatiehandleiding voor {categorie_naam} DYNAPAR HS35IQ Series. DYNAPAR HS35IQ Series 7 pagina's. Heavy duty hollowshaft encoder
LED Operation
The HS35iQ encoder revolutionizes troubleshooting by indicating
specific faults via four onboard LED indicators, a digital output, and
recorded event log fault history via PulseIQ™ Software. These options
all allow the user to make smarter decisions so you can get back up and
running faster while simultaneously giving you positive confirmation
that you have fixed the problem. A summary of the light patterns is
shown in the table below. Under normal operation all LEDs will turn
off or "Pulse" once every 2 seconds. The color of each of the lights
Fault
Fault Condition
Internal encoder
F C
temperature exceeds
operating conditions
Over-Temperature
Detection of shaft
slippage
Shaft Slip/
Overspeed detection
Overspeed
Cable open or short
condition such as
damaged cable, touching
Cable Integrity
or loose conductors*
Electronics and voltage
monitoring
Encoder Internal
Health
*Cable Integrity fault detection only available for certain decodes. Refer to decode table for more information.
White
Green
LED pulses
LED pulses
LED pulses
white when
green during
red during
fault is
normal
disabled
operation
condition
Worldwide Brands:
NorthStar
•
™
Customer Service:
Headquarters
Tel: +1.800.234.8731
2100 West Broad St.
Elizabethtown, NC 28337
USA
©2023 Dynapar. All rights reserved. Specifications subject to change without notice. Document No. 703409-0002, Rev. B
also indicates the status of the defined fault conditions. A
indicates normal operation and no problems have been detected.
A
red
light indicates the encoder is currently and actively experiencing
a fault. A "flicker" or rapidly flashing
happened within the last 30 minutes but has since been corrected.
An
orange
light indicates that the encoder is currently and actively
experiencing a warning which may transition to a fault near-term.
Finally, a
white
light indicates that the fault is inactive or has
been disabled.
Operation
Red
Blue
(Fault Recovery)
(Warning)
LED pulses
orange for
temperature
LED "flickers"
(rapidly flashes)
blue for
30 minutes after
fault
fault is corrected
or cleared. Event
logged in onboard
memory.
LED pulses
orange for
Dynapar
•
Hengstler
•
Harowe
™
™
™
Technical Support
Tel.: +1.800.234.8731
green
blue
light indicates a fault
Corrective Action
Orange
Sequence
Verify ambient temperature on
and around the encoder is within
acceptable limits.
warning
Stop rotation. Tighten coupling.
Restart and monitor.
N/A
Check motor controls
Verify all cables are properly secured
N/A
to the encoder and no damage or
shorts are noticed.
Check for sufficient voltage at encoder
encoder
connector and/or review Instructional
health
Manual for additional guidance.
warning
WWW.DYNAPAR.COM
European Sales Representative
Hengstler GmbH
Uhlandstrasse 49, 78554 Aldingen
Germany
www.hengstler.com
light