Ordering Information
This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.
MT
4
W
-
-
❶ Input type
DV: DC voltage
01)
DA: DC current
AV: AC voltage
02)
AA: AC current
02)
❸ Preset output + Sub output
Preset output
N
None (indicator)
0
Relay
1
Relay
2
NPN open collector
3
PNP open collector
4
NPN open collector
5
PNP open collector
6
NPN open collector
7
PNP open collector
8
NPN open collector
9
PNP open collector
01)  To measure the current over DC 5 A, please select DV type because the shunt should be used.
02) In case of selecting frequency display, no output will be provided even if it is output support model.
Product Components
• Product
• Bracket × 2
Manual
For proper use of the product, refer to the manuals and be sure to follow the safety
considerations in the manuals.
Download the manuals from the Autonics website.
Software
Download the installation file and the manuals from the Autonics website.
■ DAQMaster
It is the comprehensive device management program for Autonics' products, providing
parameter setting, monitoring and data management.
Dimensions
• Unit: mm, For the detailed drawings, follow the Autonics website.
■ Indicator / Relay preset output model
96
■ NPN / PNP open collector preset output model
96
■ Bracket
73
❷ Power supply
1: 12 - 24 VDCᜡ ± 10 %
4: 100 - 240 VACᜠ ± 10 % 50 / 60 Hz
Sub output
Transmission (DC 4 - 20 mA)
-
BCD Dynamic
BCD Dynamic
Transmission (DC 4 - 20 mA)
Transmission (DC 4 - 20 mA)
Low speed serial
Low speed serial
RS485 Communication
RS485 Communication
• Instruction manual
• Unit sticker × 1
6
100
6
89.5
14.9
■ Panel cut-out
≥ 116
92
+0.8
0
Cautions during Wiring
Use the Copper-conductor wire with the temperature class 60 ℃.
• Unit: mm, Use terminals of size
• Contact the manufacture for the socket and
specified below.
≥3.5
≤7.0
Connections
■ Input
• DC voltage
SOURCE
12 - 24 VDCᜡ 5 W
100 - 240 VACᜠ
50 / 60 Hz 5 VA
HOLD / ZERO
1
2
3
4
5
6
7
8
9
250 mVDCᜡ / 50 mVDCᜡ
5 VDCᜡ / 1 VDCᜡ
50 VDCᜡ / 10 VDCᜡ
500 VDCᜡ / 100 VDCᜡ
COM
• AC voltage
SOURCE
12 - 24 VDCᜡ 5 W
100 - 240 VACᜠ
50 / 60 Hz 5 VA
HOLD / ZERO
1
2
3
4
5
6
7
8
9
2 VACᜠ / 1 VACᜠ
20 VACᜠ / 10 VACᜠ
110 VACᜠ / 50 VACᜠ
500 VACᜠ / 250 VACᜠ
COM
■ Output
• 0: Relay + Transmission (DC 4 - 20 mA)
Main OUT
Contact OUT: 250 VACᜠ 3A 1a
DC 4 - 20 mA
resistive load
Load 600 Ω Max.
10
11
12
13
14
15
mA
HI
GO
LO
COM
• 2: NPN open collector + BCD Dynamic
Main OUT: NPN open collector
12 - 24 VDCᜡ Max. 50 mA
B
D
D1
D3
DOTCOM2
2
4
6
8
10
12
14
16
18
20
+24 VDCᜡ
GO
30mA Max.
BCD OUT
(NPN open collector)
12 - 24 VDCᜡ Max. 50 mA
0V
1
3
5
7
9
11
13
15
17
19
COM1
HI
LO
A
C
D0
D2
POL
• 4: NPN open collector +
Transmission (DC 4 - 20 mA)
Main OUT: NPN open collector
12 - 24 VDCᜡ Max. 50 mA
2
4
6
8
10
12
14
16
18
20
+24 VDCᜡ
-
GO
30mA Max.
DC 4 - 20 mA
Load 600 Ω Max.
0V
+
1
3
5
7
9
11
13
15
17
19
COM1
HI
LO
• 6: NPN open collector + Low speed serial
Main OUT: NPN open collector
12 - 24 VDCᜡ Max. 50 mA
POL
CLOCK
LATCH
2
4
6
8
10
12
14
16
18
20
+24 VDCᜡ
GO
30mA Max.
Serial OUT
(NPN open collector)
12 - 24 VDCᜡ Max. 50 mA
0V
1
3
5
7
9
11
13
15
17
19
COM1
HI
LO
COM2 DATA
• 8: NPN open collector + RS485 Comm.
Main OUT: NPN open collector
12 - 24 VDCᜡ Max. 50 mA
2
4
6
8
10
12
14
16
18
20
+24 VDCᜡ
B (-)
SG
GO
30mA Max.
RS485
0V
A (+) SG
1
3
5
7
9
11
13
15
17
19
COM1
HI
LO
cable.
Model
Hirose connector
HIF3BA-20PA-2.54DS
Hirose connector socket HIF3BA-20D-2.54R
2
20
19
1
• DC current
SOURCE
12 - 24 VDCᜡ 5 W
100 - 240 VACᜠ
50 / 60 Hz 5 VA
HOLD / ZERO
1
2
3
4
5
6
7
5 mA / 2 mA
50 mA / 4 - 20 mA
500 mA / 200 mA
5 A / 2 A
COM
• AC current
SOURCE
12 - 24 VDCᜡ 5 W
100 - 240 VACᜠ
50 / 60 Hz 5 VA
HOLD / ZERO
1
2
3
4
5
6
7
100 mA / 50 mA
500 mA / 250 mA
1 A
5 A / 2.5 A
COM
• 1: Relay
Main OUT
Contact OUT: 250 VACᜠ 3A 1a
resistive load
10
11
12
13
14
HI
GO
• 3: PNP open collector + BCD Dynamic
Main OUT: PNP open collector
12 - 24 VDCᜡ Max. 50 mA
B
D
D1
D3
2
4
6
8
10
12
14
16
+24 VDCᜡ
GO
30mA Max.
BCD OUT
(PNP open collector)
12 - 24 VDCᜡ Max. 50 mA
0V
1
3
5
7
9
11
13
15
COM1
HI
LO
A
C
D0
D2
• 5: PNP open collector +
Transmission (DC 4 - 20 mA)
Main OUT: PNP open collector
12 - 24 VDCᜡ Max. 50 mA
2
4
6
8
10
12
14
16
+24 VDCᜡ
-
GO
30mA Max.
DC 4 - 20 mA
Load 600 Ω Max.
0V
+
1
3
5
7
9
11
13
15
COM1
HI
LO
• 7: PNP open collector + Low speed serial
Main OUT: PNP open collector
12 - 24 VDCᜡ Max. 50 mA
POL
2
4
6
8
10
12
14
16
+24 VDCᜡ
GO
30mA Max.
Serial OUT
(NPN open collector)
12 - 24 VDCᜡ Max. 50 mA
0V
1
3
5
7
9
11
13
15
COM1
HI
LO
• 9: PNP open collector + RS485 Comm.
Main OUT: PNP open collector
12 - 24 VDCᜡ Max. 50 mA
2
4
6
8
10
12
14
16
+24 VDCᜡ
B (-)
SG
GO
30mA Max.
RS485
0V
A (+) SG
1
3
5
7
9
11
13
15
COM1
HI
LO
8
9
8
9
15
LO
DOTCOM2
18
20
17
19
POL
18
20
17
19
CLOCK
LATCH
18
20
17
19
COM2 DATA
18
20
17
19