TWN.1
T1
T2
POWER
RESET
T1 contact
T2 contact
T1
Setting time
T2
UP
0
T1
Setting time
T2
DOWN
0
1. Power: ON, simultaneously time starts
2. Progressing time = Setting time T1 → T1 contact: ON,
T2 contact: OFF, initializing progressing time and progressing
again
3. Progressing time = Setting time T2 → T1 contact: OFF,
T2 contact: ON,
display value: Hold
4. RESET signal: ON → Display value and T1, T2 contact
: return to the initial status
Ta
Rt
T1
T2
POWER
T1
T1 contact
T2
T2 contact