DCI DigiTrak FALCON F5 Sub-k Rebar Supplement handleiding - Pagina 10
Blader online of download pdf Supplement handleiding voor {categorie_naam} DCI DigiTrak FALCON F5 Sub-k Rebar. DCI DigiTrak FALCON F5 Sub-k Rebar 16 pagina's. Full scale sensitive pitch (fssp) frequency optimizer update and other recent updates
D
C
IGITAL
ONTROL
10. Pair the transmitter by aligning the IR ports (the divot on the transmitter and the small round port in
the upper center portion of the receiver front) and clicking the trigger.
11. After pairing, the transmitter defaults to using the Down band. Calibrate with the transmitter in a
housing in both the Up and Down bands, then perform an AGR test as described in the Falcon F5
operator's manual.
Full Scale Sensitive Pitch (FSSP)
FSSP mode requires an FSSP-capable transmitter. FSSP provides 0.1% pitch resolution throughout the
entire range of ±99.9% slope for precision grade work.
FSSP is included on Falcon F5 19" and 15" fluid pressure transmitters with software v2.1.1.0 or
higher. You can view a transmitter's software version by selecting Transmitter selection
from the Main menu, then Transmitter information
request
while holding the IR port to the receiver as if you were pairing. If you select FSSP
mode while pairing but it is not available on the transmitter, the transmitter will pair but only
provide the standard pitch resolution.
After the transmitter pairing request screen, select Transmitter pairing request 0.1%/100% (#2 below).
Transmitter Pairing Request Screen
Standard transmitter pairing (#1 above) yields lower pitch resolution as the pitch increases:
But in FSSP mode, the FTP transmitter retains and transmits 0.1% resolution at all times within ±99.9%
slope.
6
I
NCORPORATED
±% Grade
± Degrees Grade
0 – 3%
0 – 1.7°
3 – 9%
1.7 – 5.1°
9 – 30%
5.1 – 16.7°
30 – 50%
16.7 – 26.6°
50 – 90%
26.6 – 42.0°
, then Transmitter information
1. Standard pitch mode
2. FSSP mode
% Resolution
0.1%
0.2%
0.5%
2.0%
5.0%
Supplement B for DigiTrak ® Falcon F5 ®