DynaTrap DT150-CA Gebruikershandleiding
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} DynaTrap DT150-CA. DynaTrap DT150-CA 2 pagina's.
DT150-CA
OWNER'S MANUAL
Thank you for purchasing
the DynaTrap
Insect Trap!
®
This product may be covered by one or more U.S. patents
or pending patent applications. See www.DynaTrap.com/patents
IMPORTANT: READ CAREFULLY
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
WARNING:
when using electric appliances, basic precautions should
always be followed, including the following:
– To disconnect, remove plug from outlet.
– Unplug from outlet when not in use and before servicing or cleaning.
– To reduce the risk of electrical shock, do not put appliance in water or other liquid.
– This appliance is provided with double insulation. Use only identical replacement parts.
CAUTION:
To reduce the risk of injury from moving parts, unplug before servicing.
WARNING:
Risk of Electric Shock.
See instructions for Servicing of Double-Insulated Appliances.
IMPORTANT SAFETY INSTRUCTIONS
Please read all instructions before using the DynaTrap ® Insect Trap and keep for future reference.
1.
2.
To disconnect, remove plug from outlet.
3.
To reduce the risk of injury from moving parts or electric shock, always disconnect plug before servicing or
cleaning.
4.
Do not position the unit near heat, gas, oil or other flammable materials.
5.
Place out of reach from children.
6.
To reduce the risk of electrical shock, do not put appliance in water or other liquid.
7.
Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped
or damaged, or if it has been dropped into water or other liquid.
8.
Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).
9.
Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.
10. Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.
11. Do not clean this product with water spray. Do not place where it can fall into water, or near flammable
materials.
12. Do not touch fan while in motion.
13. Do not abuse cord—never carry or hang unit by cord or yank it to disconnect from receptacle. Keep cord away
from sharp edges.
14. Use only extension cords that have plug and receptacles that match the product plug. Replace or repair
damaged cords.
15. Only use attachments recommended or sold by the manufacturer.
16. This appliance is provided with double insulation. Use only identical replacement parts. See instructions or
Servicing of Double-Insulated Appliances.
INSTALLATION & OPERATING INSTRUCTIONS
1.
Unpack unit. Save carton for off-season storage (if needed).
2.
The unit will turn on automatically when plugged in. For best catch results, leave the trap on and running, 24/7.
3.
Catch rate activity will be higher at night. For best catch results it is recommended to keep the unit away from
competing light sources.
4.
It is recommended to place the unit at least 20 to 40 feet away from where people will be sitting.
5.
This unit is for household and commercial, indoor use only.
6.
SERVICING OF DOUBLE-INSULATED APPLIANCES - In a double-insulated appliance, two systems of insulation are
provided instead of grounding. No grounding means is provided on a double-insulated appliance, nor should a
means for grounding be added to the appliance. Servicing of a double-insulated appliance requires extreme care and
knowledge of the system and should be done only by qualified service personnel. Replacement parts for a double-
insulated appliance must be identical to those parts in the appliance. The symbol must be identical to those parts in
the appliance. A double-insulated appliance is marked with the words "DOUBLE INSULATION", "DOUBLE-INSULATED"
FOR
or the symbol:
INDOOR USE
7.
The electrical adapter provided with this product is equipped with a 2-conductor cord and a 2-prong plug as a safety
feature. If the plug does not fully fit in the outlet, contact a qualified electrician. To reduce the risk of electrical shock,
only plug into a properly installed outlet. Do not attempt to defeat this safety feature.
FCC COMPLIANCE
This device complies with part 18 of the FCC rules. This product may cause interference to radio equipment and should not
be installed near maritime safety communications equipment or other critical navigation or communication equipment
operating between 0.45-30 MHz. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
CLEANING
Frequent cleaning will prolong the life of the unit, ensure fire prevention and provide for more efficient operation.
1.
Be sure to clean the unit at least once per week.
2.
Unplug the unit. CAUTION: There may be insects still alive when opening the trap.
3.
For weekly cleaning, remove the cage by turning it clockwise.
Remove any buildup from the inside of the retaining cage and fan with a brush.
4.
When replacing the retaining cage – DO NOT press/push against the screen windows.
5.
Clean prior to storage.
HOW THE DYNATRAP
Mosquitoes are attracted to the unit
by the UV light. The fan then pulls the
mosquitoes into the screened base,
trapping them until they dehydrate and
die. The base can be removed, allowing the
contents to be periodically emptied into the
trash. Monitor the mosquitoes trapped in
the retaining cage through the see-through
screen, and empty when compartment
becomes full.
MOSQUITO TRAP WORKS
®
UV
BULB
FAN
RETAINING
CAGE
TROUBLESHOOTING
Problem:
Possible cause:
Correction:
Bulb does not illuminate
No electrical power.
1. Check plug, receptacle, fuse or circuit breaker.
and fan does not spin.
Bulb illuminates, but fan
Shorted fan.
UNPLUG UNIT: Examine fan to see that it is free from
does not spin.
foreign material, dirt or buildup of dead insects.
Clean unit as in "CLEANING" section.
Fan spins, but bulb does
Burnt out bulb.*
The UV-Lamp has an expected lifespan of 20,000 hours and
not illuminate.
is not replaceable.
If lamp fails to illuminate before 20,000 hours of operation,
call customer service at 877-403-8727.
LIMITED WARRANTY
DYNAMIC guarantees to the original purchaser that this product is free from defective materials and workmanship.
This warranty is limited to remedy any defective part for a period of one year from date of original date of purchase.
Retain your original receipt as proof of purchase. This warranty does not apply to the light bulb, nor to, in our
judgment, misuse or abuse. If this unit has been altered, no warranty is in force. This warranty does not apply if this
unit is purchased outside the United States, Canada and Mexico. In no case shall DYNAMIC be liable for any accidental,
punitive, consequential, or any other damages of any kind for breach of this or any other warranty, expressed
or implied, whatsoever. Some states do not allow limitation on how long an implied warranty lasts, so the above
limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have
other rights that vary from state to state.
SAVE THESE INSTRUCTIONS
FOR HOUSEHOLD AND COMMERCIAL,
INDOOR USE ONLY
Unit Rated Voltage: 12Vdc 7W
Use Included Power Supply Only:
Input: 100 - 240V~ 50/60 Hz Output: 12Vdc 0.5A
Dynamic Solutions Worldwide, LLC
69 N. Locust St., Lititz, PA 17543
1-877-403-8727 (TRAP)
www.dynatrap.ca
Imported by/Importé par:
Woodstream Canada Corporation
25 Bramtree Court, Unit 1
This device complies with Performance Standards for
Brampton, ON L6S 6G2
Light-Emitting Products, 21 CFR, Part 1040, Chapter 1,
© Dynamic Solutions Worldwide, LLC
Subchapter J, Radiological health.