STEP 4
REPLACE THE OVEN BAKE AND BROILER BURNER ORIFICES
To replace the bake burner orifice:
1. Open and remove the oven door (refer to range installation instructions). Remove racks.
2. Remove the two screws that retain the convection inlet spout to the convection baffle and remove spout.
3. Pull the oven bottom panel forward and remove from the oven.
4. Remove the retaining screw from the left end of the bake burner. Slide burner to the left, off of orifice and
out of burner box.
5. Using the 1/2" deep socket, remove the bake burner orifice.
6. Verify that the orifice size in the kit matches the chart size and replace the burner orifice.
7. Reinstall the bake burner on the orifice and fasten to burner box with screw.
Do not reassemble oven bottom at this time.
To replace the broiler burner orifice:
1. Remove the four black screws that fasten the door latch access panel to the front frame. Pull panel forward.
2. Remove the broiler orifice/air shutter cover located on the right side of the recessed area where the door
latch is located. Note the location of the insulation strip under the edge of the cover.
3. Locate the orifice elbow on the end of the broiler burner venturi. The orifice is fastened to the far side of
the elbow. Using the appropriately sized wrench, remove the orifice from the elbow.
4. Verify that the orifice size in the kit matches the chart size and replace the burner orifice.
Do not re-assemble air shutter cover or access panel at this time.
OVEN BURNER ORIFICES
LOCATION
NATURAL
SIZE
MARKING
BAKE
#40 DMS
BROILER
#50 DMS
STEP 5
CHECK FOR LEAKS
WARNING
Check for leaks before attempting to light the burners or use the oven.
Check to be sure all controls are in the OFF position.
Turn on the gas supply at the shut-off valve.
Use a leak detector at all connections. If a leak is detected, tighten the connection and test again.
DO NOT USE A FLAME TO CHECK FOR GAS LEAKS.
RATE
SIZE
40
28.0K Btu/hr #53 DMS
50
15.0K Btu/hr #56 DMS
LP
MARKING
RATE
53
25.0K Btu/hr
56
15.0K Btu/hr