D100348X012
Table 1. Specifications
(1)
Port Diameters
Supply Port: J 9.5 mm (0.375 inch) or J 12.7 mm
(0.5 inch)
Exhaust Port: J 2.4 mm (0.094 inch)
(0.375 inch) or J 12.7 mm (0.5 inch)
Input Signal
Positioner output
Maximum Input Signal Pressure
10.3 bar (150 psig)
Input to Output Pressure Ratio
Fixed at 1 to 1
Supply Pressure Ranges
When used in conjunction with a positioner or other
pneumatic accessory, always pipe the positioner and
booster with one common supply through a Fisher
67D, 67DR, or MR95H regulator (see figure 3). A
high‐capacity filter, such as the Fisher 262K, should
be installed in the supply line to the regulator. Supply
pressure also must not exceed the maximum
pressure rating of the actuator. Constructions are
available in two maximum supply ranges.
When Normally Used With Diaphragm Actuators: Up
to 2.8 bar (40 psig)
When Normally Used With Piston Actuators: Up to
10.3 bar (150 psig)
(4)
Nominal Deadband
Percent of Positioner Output Span
2.4 mm (0.094 inch) exhaust port: 2%
9.5 mm (0.375 inch) exhaust port: 3.5%
12.7 mm (0.5 inch) exhaust port: 5%
Operative Temperature Limits
2625/2625SST
Standard: -40 to 71_C (-40 to 160_F)
High Temperature: 0 to 121_C (32 to 250_F)
2625
(5)
Low Temperature
: -60 to 65_C (-76 to 149_F)
2625NS: -40 to 93_C (-40 to 200_F)
1. May be used in any combination.
2. Aluminum 2625 volume booster only.
3. The pressure/temperature limits in this document, and any applicable code or standard limitation should not be exceeded.
4. This term defined in ISA Standard S51.1
5. Low Temperature option only available with CUTR approval.
6. Zero psig to maximum supply.
(2)
, J 9.5 mm
(3)
(6)
:
(3,4)
2625, 2625SST, and 2625NS Volume Booster
Maximum Flow Coefficients
See table 2
Connections
Input Signal: 1/4 NPT
Supply and Output Signal: 3/4 NPT
Hazardous Area Classification
Complies with the requirements of ATEX Group II
Category 2 Gas and Dust
Maximum surface temperature (Tx) depends on
operating conditions
Gas:
T4, T5, T6
Dust:
T85...T121
Meets Customs Union technical regulation TP TC
012/2011 for Groups II/III Category 2 equipment
II Gb c T*X X
III Db c T*X X
Safety Instrumented System Classification
SIL3 capable - certified by exida Consulting LLC
Approximate Weight
Aluminum: 2.3 kg (5 pounds)
Stainless Steel: 4.8 kg (10.6 pounds)
Declaration of SEP
Fisher Controls International LLC declares this
product to be in compliance with Article 4 paragraph
3 of the PED Directive 2014/68/EU. It was designed
and manufactured in accordance with Sound
Engineering Practice (SEP) and cannot bear the CE
marking related to PED compliance.
However, the product may bear the CE marking to
indicate compliance with other applicable EC
Directives.
September 2022
Ex h IIC Tx Gb
Ex h IIIC Tx Db
3