OPERATION
Running an EDID Capture
Before using the Isolator, run a one-time EDID capture. This
prevents the continuous transfer of potentially malicious data -
from the display to the PC – that could infect the PC, cause data
leakage, and so on.
Preparation:
•
Connect the PC and all peripherals to the unit, according to
the diagram.
•
Make sure the PC, display, and unit are ON.
To run an EDID capture:
1.
On the PC SIDE, short-click the CAPTURE button – for less
than one second. Warning: Long-clicking the CAPTURE
button sends the unit into an undesired loop. If this
happens, restart the unit and repeat the procedure.
At first, the EDID LED flickers for a few seconds and then
lights continuously.
Note: If the EDID LED is OFF, check the connections and
that the display is powered ON. Then, repeat the
procedure.
2.
Restart the unit.
HSL Secure 2-Port KVM Combiner Quick Setup Guide
1
2
Note: An EDID capture needs to be performed for new installations and
when changing a display.
3
7