ADESCO MQ03 LTE-M Installatie- en configuratiehandleiding - Pagina 9

Blader online of download pdf Installatie- en configuratiehandleiding voor {categorie_naam} ADESCO MQ03 LTE-M. ADESCO MQ03 LTE-M 11 pagina's. Global sim universal communicators

Check the "Enable Online Settings" check box as shown below
Press "Get Current Settings" button to read settings from the device. The device should be powered and connected to the server, otherwise
these fields will be disabled. From the COM Settings section select "None" in the Tunnel field and select "DTMF2" working modes in the Events
field. This will automatically populate the correct baud rate and format (4800, 8n1). Press "Save" button.

Account number reporting modes

You can choose if the events from the DTMF dialer of the alarm panel will be transmitted with the Account number that is programmed on the
panel itself, or with the Account number (SiteNo) of the communicator.
From the administrative web site, navigate to the Menu 'Commands' -> Alarm Settings. In the COM settings section, if DTMF mode is selected,
you will see "Keep DTMF Account Number" checkbox. If it is checked, the alarm events will be transmitted with the account number that is
specified in the alarm panel itself. This can be useful when you want to specify different account number for the different p artitions in the alarm
panel. Note: the events that are generated from the MQ03 communicator itself will be still reported with the SiteNo, specified in the alarm
settings page for that communicator.
If you uncheck the "Keep DTMF Account Number" checkbox, all events will be reported with Account Number of the communicator. This is useful
when you want to easily change the Account number without having to reprogram the alarm panel.

Connecting alarm panels via the serial port

MQ03 communicators support integration via the serial port with some alarm panels. Please verify that the model of the communicator supports
your panel. For MQ03 communicators, verify that you have also purchased appropriate cable.

Selecting the type of the alarm panel

From the administrative web site, navigate to the Commands->Alarm Settings page. Check the "Enable Online Settings" check box and press
"Get Current Settings" button to read settings from the device. The device should be powered and connected to the server, otherwise these
fields will be disabled. From the COM Settings section select "None" in the Tunnel field and in the Events field select the brand and the model of
the panel that you are connecting via the serial port. This will automatically populate the correct baud rate and format. You can change these
settings if needed. For some alarm panels you might need to specify passwords that give the communicator access to the panel. Press the "Save"
button.
See below for alarm panel specific settings.
GSM/GPRS Communicator MQ03 Installer Manual Version 1.1
page 9 of 11