Test Settings: General OTDR Test Modes
Setup
Parameter
Full Auto
Wavelength User selects single or multiple wavelength(s) at which to test.
Auto Setup
N/A
(not applicable)
Range
N/A: automatic
Pulse width N/A: automatic,
based on auto-
detected range
Averaging
Resolution
N/A: automatic
Range: When setting manually, select [Range],
which is at least 20% longer than the fiber under
test.
Pulse width [Pulse]: Select wider pulse widths to
obtain cleaner traces (less noisy). Select narrower
pulse widths to detect events which are close
together (better resolution).
General-Purpose OTDR Test Mode
Real Time
[Off]: User sets all parameters manually.
[By Range]: User sets [Range] & [Resolution], [Pulse width] &
[Averaging] selected automatically.
User sets OTDR scan range.
Automatic if [Auto Setup] parameter is set to [By Range] option.
User-set if [Auto Setup] parameter is set to option [Off].
N/A: 1 second
Automatic if [Auto Setup] is set to [By Range].
updates
User-set if [Auto Setup] is set to [Off].
User-set [High] or [Normal].
6
Expert
Averaging Time [Averaging]: Longer averaging
times produce cleaner traces.
Resolution: [High] resolution provides close data
spacing for more precise event location and better
detection of closely spaced events. [Normal]
resolution uses more filtering to provide a cleaner
trace, but with lower resolution.