Event Notifications and Reports

The CS1060 Sensor has six (6) configurable event triggers that can be used to monitor the
changing temperature and humidity conditions. When event thresholds are exceeded, the
Sensor uplinks a notification indicating the event and current temperature conditions. Using the
configuration messages for the device, the Sensor can report the following information:
Event Notifications – Triggered notifications based on evaluating sampled temperature
and humidity data.
Periodic Reports – Report samples of temperature and humidity data. Can configure
intervals from one minute to 44 days.
Periodic Statistics – Report temperature and humidity statistics at regular intervals from
one minute to 44 days.
Statistics reports provide:
Average values
Maximum/ Minimum values
Variances
Count of samples
Statistics are stored in non-volatile memory and will persist through a battery change or dead
battery. Both the statistic reporting and event notifications can be configured remotely by
sending downlink messages.
The sensor has a periodic Heartbeat / Battery-status message that is sent to maintain
LoRaWAN network connectivity and indicate battery status information. The period may be
configured between two (2) minutes minimum and 48 hours maximum.

Reset Notifications

FACTORY RESET uplink messages will be sent after rebooting.

Firmware Version

The firmware information can be retrieved via sending a downlink command.
CS1060 Temperature & Humidity Sensor – User Guide