3.
Connect water
Connect the water supply to the strainers
and turn on water supply. Check for leaks.
Adaptors supplied by the installer must be in
accordance with AS/NZS 3500.
Do not apply heat near this product. Heat
generated by soldering could damage plastic
or electrical parts and seals and will void the
warranty.
Version 2, 30 August 2017, Page 5 of 8
Typical Installation
4. Mount control module
Fit the four mounting feet supplied with the
control module to the back of the controller
module box. Measure the holes between centres
as shown in pre-installation page of control
module dimensions.
Find a suitable place to mount the control
module within 5mtrs of the service and 4mtrs of
the GPO.
Mark out and drill holes 5.0, mount the control
module with supplied fasteners
All electrical components should be protected
from contact with water or excessive heat and
installed in accordance with local regulations.
If non-standard control module (52504X) is
required fill in timings on supplied drawing
sheet with controller box.