Galvin Engineering CliniMix 100.91.10.20 Installatie Manuals - Pagina 4
Blader online of download pdf Installatie Manuals voor {categorie_naam} Galvin Engineering CliniMix 100.91.10.20. Galvin Engineering CliniMix 100.91.10.20 4 pagina's. Bs lead safe thermostatic cartridge assembly for cmv2 low flow
Product Installation Guidelines
TROUBLESHOOTING
PROBLEM
Water is not flowing
Mixed water is not correct
WARRANTY
The warranty set forth herein is given expressly and is the only warranty given by the Galvin Engineering Pty
Ltd. With respect to the product, Galvin Engineering Pty Ltd makes no other warranties, express or implied.
Galvin Engineering Pty. Ltd. hereby specifically disclaims all other warranties, express or implied, including
but not limited to the implied warranties of merchantability and fitness for a particular purpose.
alvin Engineering Pty Ltd products are covered under our manufacturer's warranty available for download
from www.galvinengineering.com.au Galvin Engineering Pty Ltd expressly warrants that the product is free
from operational defects in workmanship and materials for the warranty period as shown on the schedule in
the manufacturer's warranty. During the warranty period,
defective products manufactured by Galvin Engineering without charge, so long as the terms of the
anufacturer's warranty are complied with.
The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy
for breach of warranty, and Galvin Engineering Pty Ltd shall not be responsible for any incidental, special or
consequential damages, including without limitation, lost profits or the cost of repairing or replacing other
property which is damaged if this product does not work properly, other costs resulting from labour charges,
delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions,
chemical, electrical or any other circumstances over which Galvin Engineering has no control. This warranty
shall be invalidated by any abuse, misuse, misapplication, improper installation or improper maintenance or
alteration of the product.
CAUSE
Water manis closed
Power mains off
Unit not re-commitioned
Supply water conditions out
of requrements
RECTIFICATION
Open water main supply, ensure
isolation valves are in open position
Turn on the power
Re-commision the mixer as per units
installation instruction
Ansure water supply conditions are as
per requirements (see units installation
instruction for details)
alvin Engineering will replace or repair any
Version 1, 14 September 2022, Page 4 of 4