Galvin Specialised CliniLever TCWTJ80PC Product Installatie Manuallijn - Pagina 3
Blader online of download pdf Product Installatie Manuallijn voor {categorie_naam} Galvin Specialised CliniLever TCWTJ80PC. Galvin Specialised CliniLever TCWTJ80PC 4 pagina's. Healthcare tapware
TROUBLESHOOTING
PROBLEM
Taps are dripping water
Water is leaking from spindle
Water is not flowing from tap
Spindle is difficult to turn
(jumper valve)
Handle is loose
Flange does not screw down onto
wall surface
SERVICE AND MAINTENANCE
1. Turn off the water supply and turn on the tap handle to drain water from the bodies.
2. Remove the temperature indicator from the handle.
3. Remove the handle from the tap.
4. Unscrew the top assembly from the body.
5. Check the o-ring on the spindle and the jumper valve for wear and damage. Replace if required.
6. Clean the spindle and body of debris.
7. Place a new o-ring (if required) onto the spindle and re-grease with potable water approved grease.
8. Re-assemble top assembly. Follow the product installation guidelines for the relevant product
re-assembly method.
CAUSE
Jumper valves are worn or damaged
Tap seat is damaged
O-ring on jumper valve spindle is
damaged or worn
Water is turned off
Aerator or flow regulator is blocked by
debris
Build up of scale on spindle, spindle
worn or o-ring has been damaged
Screw has come loose
Wall bodies are set too far out
JUMPER VALVE TAPWARE
RECTIFICATION
Replace jumper valve
Refurbish tap seat using a reseating
tool.
Replace o-ring
Turn on water
Remove aerator and/or flow
regulator from tap and remove
debris. Install an inline strainer.
Remove jumper valve, clean and
regrease. Replace o-ring. Complete
SBA may need to be replaced.
Tighten handle screw
Re-position tap bodies