Coram TUBULAR SHOWER PANELS Snelstarthandleiding - Pagina 6

Blader online of download pdf Snelstarthandleiding voor {categorie_naam} Coram TUBULAR SHOWER PANELS. Coram TUBULAR SHOWER PANELS 9 pagina's.

6
a
d
PN80456
a: Remove the strut from the panel, place an inner wall bracket in the marked position and mark the
fixing hole onto the wall.
b: Drill the position marked using a 6mm drill bit, 30mm deep.
c: Insert the wall plug and fix the inner wall bracket to the wall using a 38mm screw and washer.
Note: The screws and wall plugs supplied are for masonry walls. For lightweight walls i.e.
stud partitions, plasterboard etc, use the correct type of fixings.
8
a
b
ø 6
mm
Place the second wall channel in position against the wall.
a: Ensure the wall channel is vertical and mark the four holes onto the wall.
b: Drill the four positions marked using a 6mm drill bit.
c: Apply silicone sealant to the back of the wall channels
d: Insert the wall plugs. Place washers over the 32mm screws and fix the wall
channel to the wall. If necessary, slight adjustment is available in the wall channel.
b
c
ø 6
mm
38
mm
e
f
d: Slide the strut bracket and wall bracket cover onto the strut.
e: Reposition the strut into the inner wall bracket and the other end (with panel bracket fitted)
onto the glass panel (with grub screws on the inside). Screw the wall bracket cover onto the
inner wall bracket.
f: Tighten the wall bracket cover grub screw.
g: From inside, slide the glass clamp up between the bracket and glass panel, tighten the
grub screw (1). Ensure the panel is vertical and tighten the grub screw in the top of the panel
bracket (2).
9
c
d
32
mm
Slide both seals down into the wall channel and cut
off any excess.
Note the orientation of the soft flippers.
g
2
1
Inside
10
IMPORTANT
Ensure Glass Guard H2o
label is to the outside of
the enclosure/panel
Satin glass patterns must
be installed to the outside
of the enclosure.
Note:
The Glass Guard coating is
on the opposite side to the
label or satin glass patterns
Carefully push the panel into the wall channel.
Note: Wetting the edge of the panel with water will
help the panel insert.
7
Max.
opening
880mm
Plan the position for the second panel, the opening can be a
maximum of 880mm.
11
PN60154
16
mm
Attach the wall bracket assembly to the strut bracket using the
16mm screw.
PAGE 6