INSTALLATION
Panel Mounting
The panel is designed for surface mounting using four screws. Removing the cover on the panel provides
access to the circuit board and mounting holes. Once the mounting and connections are finished –
secure the front panel cover with the supplied bolts and security caps.
DPM2 Wiring
A 110-120Vac supply should be connected to the terminal [MERLIN PANEL L N E] and fused at 3A.
Take care when making connections to high voltage connectors!
Any damage attempting to remove the circuit board may void any warranty!
All Class 2 wiring is to be installed within flexible tubing to maintain segregation between circuits!
Wiring of different circuits shall be separated from each other by means of routing, clamping or barrier!
Rev 04
09-20
User Guide
2