Programming Instructions

Each transmitter has its own unique internal address along with the data as to which button is pressed and transmitted.
The receiver needs to be programmed to respond only to the specific transmitter it is intended to operate with. The
following steps configure the receiver to operate with a particular transmitter. Up to 30 transmitters can be programmed
to one receiver. Please read the entire programming procedure before starting. When the receiver enters program
mode, all previous transmitter addresses that were programmed will be erased from the receiver's memory.
1. Locate the pushbutton labeled "PROGRAM" on the receiver. Press and hold this button until the red LED next to the
program button illuminates (approximately 3 seconds). The receiver is now in the transmitter program mode. Release
the button. At this point all previously programmed transmitter addresses are erased from the receiver's memory.
2. To configure the receiver for a latching output, go to Step 4.
3. To configure the receiver for momentary output, press and release the UP button once on the transmitter and verify
that the red program LED extinguishes and then illuminates (blinks once). Proceed to Step 5.
4. To configure the receiver for latching output, press and release the UP button on the transmitter twice and verify that
the red program LED extinguishes and illuminates several times (blinks rapidly).
5. To add additional remote controls repeat previous steps while the control is still in program mode. Pressing the
program button after the unit has exited program mode will erase the memory. All transmitter need to be programed at
the same time while the receiver is in program mode. The red LED on the receiver will extinguish and illuminate for each
transmitter that is programmed. NOTE: Momentary or Latching operation is determined by the last transmitter that is
programmed to the receiver.
6. The receiver will exit program mode if no transmitter buttons are pressed for 5-seconds. The red LED on the receiver
will blink rapidly, then extinguish. The receiver is now in the normal mode of operation.