Dynojet Power Commander III Handmatig - Pagina 2
Blader online of download pdf Handmatig voor {categorie_naam} Dynojet Power Commander III. Dynojet Power Commander III 4 pagina's. 2007 honda cb600f
Ook voor Dynojet Power Commander III: Installatie-instructies (4 pagina's), Installatie-instructies (4 pagina's)
Installation Instructions for
Aprilia Futura
Power Commander III
The ignition MUST be turned off before installation!!
1
Remove the seat.
2
Lift up the front of the fuel tank.
3
Disconnect the wiring harness from the injector on the right
hand side of the bike by pushing up (squeeze) on the spring
clips from the injector connector (Fig. A).
Stock connector
Fig.A
2
Trouble Shooting
If you feel that you are having any problems at all with the
Power Commander III, disconnect it from your motorcycle.
This will allow the motorcycle to run directly off of the stock
ECU.
The lights don't come on when I turn the ignition switch on.
Check to make sure connectors are seated and the kill switch is
in the "run" position.
The on-board adjustment buttons do not hold their set-
tings.
Be sure to wait 20-30 seconds after making adjustments before
starting or turning off the bike.
Can not upload to or download from the Power
Commander III.
Check to see that the serial cable is firmly in place. Verify that
ignition switch is on and the kill switch is in the "run" position.
My mouse uses the same serial port.
If your computer has a PS/2 port purchase a DB9 to PS/2
adapter for your mouse.
I get a "verify failed...." message when I upload a map to
the Power Commander III.
Programs running in the background or fluctuations in supply
voltage (from outlet) can sometimes cause this error. In most
cases, the
information was sent properly to the Power
Commander III. Pushing the "upload all" button again should
produce a "tables sent and
I typed in notes, but they didn't save.
You need to first push the "accept" button in the notes window
and then the "save file" button.
verified" message.
7