Electrical & water
supply
requirements
Electrical requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3-prong
outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these
instructions can result in death,
fire, or electrical shock.
Important: Observe all governing codes
and ordinances.
If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path is adequate.
Do Not ground to a gas pipe.
Check with a qualified electrician if you
are not sure the refrigerator is properly
grounded.
Do Not have a fuse in the neutral or
ground circuit.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation
is adequate and in conformance with the
National Electrical Code, ANSI/NFPA 70
— latest edition* or Canadian Electrical
Code, C22.1-1982 and C22.2 No. 01982
(or latest edition)**, and all local codes
and ordinances.
Page 4
A 120-volt, 60-Hz, AC-only, 15- or
20-ampere, fused, electrical supply is
required. A time-delay fuse or circuit
breaker is recommended. It is
recommended that a separate circuit
serving only this appliance be provided.
This appliance is equipped with a power
supply cord having a 3-prong ground plug.
To minimize possible shock hazard, the
cord must be plugged into a mating
3-prong, ground-type outlet, grounded in
accordance with the National Electrical
Code, ANSI/NFPA 70 — latest edition* or
Canadian Electrical Code, C22.1-1982 and
C22.2 No. 01982 (or latest edition)**, and
all local codes and ordinances. See Figure 1.
If a mating outlet is not available, it is the
personal responsibility and obligation of the
customer to have a properly grounded
3-prong outlet installed by a qualified
electrician.
Warning – Improper connection of the
equipment-grounding conductor can result in
a risk of electric shock. Check with a qualified
electrician or serviceman if you are in doubt as
to whether the appliance is properly grounded.
Do not modify the plug provided with the
appliance – if it will not fit the outlet, have a
proper outlet installed by a qualified
electrician.
Copies of the standard listed may be
obtained from:
* National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
** Canadian Standard Association
178 Rexdale Boulevard
Etobicoke, Ontario M9W 1R3
3-prong ground-type outlet
3-prong ground
plug
ground prong
power supply
cord
Figure 1
Water supply requirements
Use only 1/4" (6 mm) minimum copper
tubing for water line.
Do Not install copper tubing in area
where temperatures drop below 32°F
(0°C).
Water line to refrigerator must provide