4. ASCII Pass-through Configurations

This section describes the supported features of the ASCII pass-through configuration, including AT commands,
AT registers, baud rates, and factory defaults.

4.1 Supported AT Commands

Table 2 lists the supported AT commands.
Command
+++
ATO
ATSr?
ATSr=
ATZ
AT&F
AT&MBM
AT&MBS
AT&MBC
Note: When running ASCII pass-through firmware for the first time, it is important to run the AT&F command fol-
lowed by the ATZ command. This is required to write ASCII-specific default settings to the Flash memory.

4.2 Supported AT Registers

Table 3 lists the supported AT registers.
Note that register numbers 100 and above may be used for advanced physical-level PLC configuration. The altera-
tion of these parameters from their default values is usually not required. However, in challenging circumstances,
e.g. high interference or noise, this may be an option. The applicability and meaning of such settings depends on
the PLC protocol. For more information, refer to the documents listed in Section 7, References, or contact Semi-
tech Semiconductors should fine tuning of the physical parameters be required.
Register Number
37
UART baud rate (37 is standard allocation for this purpose).
100-200
PLC PHY configuration parameters.
100
Modulation code, 0 to 6.
101
Bits per baud.
102
Number of repetitions.
103
Number of frequencies.
104
Convolution code enable.
1: enable
0: disable
105
Tone map. A bit map containing a list of the sub-bands (groups of tones) that are either active (bit set to 1) or
inactive (bit set to zero). A bit in the bit map represents a group of consecutive tones and the number of tones
per group depends on the band plan.
106
Coherent mode.
1: enable
0: disable
Table 2. Supported AT Commands
Switch to command mode.
Switch to data (string tx) mode; this command ends with Satin letter "O", not with zero.
Get Register r.
Set Register r.
Reboot device.
Restore Factory Defaults (most defaults depend on PHY, see below).
Make master.
Make slave (requires address as argument).
Run given command.
Table 3. Supported AT Registers
Description
SM2400 Serial-to-PLC Adapter User's Guide
7
UG-SM2400–-177A–-02/2019