Dea REV24/M Bedieningsinstructies en waarschuwingen - Pagina 6

Blader online of download pdf Bedieningsinstructies en waarschuwingen voor {categorie_naam} Dea REV24/M. Dea REV24/M 19 pagina's.

Dea REV24/M Bedieningsinstructies en waarschuwingen
4.5 Non self locking models
Non self locking models allow the gate to move manually, without having to use a release key when the power fails. Non self locking
versions are equipped with a holding brake when opening/closing, This means the gate will be self locking in normal operation.
Refer to the attached sheet for the correct procedure of cleaning / maintenance of the electro-brake. DEA System reminds that the
operations must be performed by qualified personnel.

5 ELECTRICAL CONNECTIONS

Run the motor connections following the wiring diagrams.
WARNING For adequate electrical safety, keep low safety voltage wires (controls, electro-locks, antenna, auxiliary power) clearly separate
from 230V ~ power wires (minimum 4 mm in air or 1 mm via supplementary insulation) placing them in plastic raceways and securing
them with adequate clamps near terminal boards.
WARNING For connection to the mains, use a multipolar cable having a minimum section 3x1,5 mm² and complying with the current
regulations. For connecting the motors, use a minimum cross section 1,5 mm² cable and complying with the current regulations. As
an example, if the cable is out side (outdoor), must be at least equal to H05RN-F, whereas if it (in a raceway), must be at least equal to
H05VV-F.
WARNING All wires must be striped and unsheathed in the immediate vicinity of terminals. Keep wires slightly longer to subsequently
eliminate any excess.
WARNING Maintain the ground conductor at a major length respect the active conductors so that, if the cable exit from its fixing housing,
the active conductors tighten up as first.
WARNING To connect the encoder to the control panel, use only a dedicated cable 3x0,75mm
WARNING For reversible models with electronic brake and without NET230N on board, remember to set the parameter P062=3 (electro-
brake output for reversible motors).
Program the control board to complete all adjustments. It is now possible to supply a complete installation in compliance with all stan-
dards required for gate automation. See the instructions provided with the control panel to be connected.
Finally, verify that all adjustments operations have been correctly performed and that safety devices and unlocking device properly
work.
.
2
EN-5