Mainstreet Equipment 829BMR23R Gebruikershandleiding - Pagina 7
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Mainstreet Equipment 829BMR23R. Mainstreet Equipment 829BMR23R 7 pagina's. Reach-in refrigerator
User Manual
TROUBLESHOOTING
Compressor is Not Running
PROBLEM
Fuse blown or circuit breaker tripped .
Power cord unplugged .
Thermostat set too high .
Cabinet in defrost cycle .
Cabinet Temperature is too Warm
PROBLEM
Thermostat is set too high .
Airflow is blocked .
Low refrigerant levels .
Door is slightly ajar .
Interior Light is Not Working
PROBLEM
Poor switch connection .
Bulb is not connected .
Bulb has burned out .
Condensation is Collecting on the Cabinet and/or Floor
PROBLEM
Gasket is not sealing properly .
Relative humidity is above 55%
Thermostat set too high .
Cabinet in defrost cycle .
Mainstreet Equipment
SOLUTION
Replace fuse or reset circuit breaker .
Plug in power cord .
Set thermostat to lower temperature .
Wait for defrost cycle to finish .
SOLUTION
Set thermostat to lower temperature .
Re-arrange products to allow for proper air flow . Make sure
there is at least four inches of clearance from the fan .
Contact a service technician to check refrigerant levels .
Make sure door is completely closed .
SOLUTION
Turn off light switch and turn it back on .
Make sure the bulb is correctly inserted in the socket .
Replace the bulb .
SOLUTION
Clean, repair, or replace the gasket as necessary .
Move unit to area below 55% relative humidity or lower
humidity level .
Set thermostat to lower temperature .
Wait for defrost cycle to finish .
7