Symptom
Tool suddenly stopped
Tool sockets
-can't be attached
-fall off
-can't be removed
Switch can't be pulled
An abnormal high-pitched noise
occurs when the trigger switch is
pulled.
Battery cannot be installed.
(WR36DH)
Possible cause
Tool was overburdened
The battery is overheated.
The trigger switch was held down for
5 minutes or more.
The shape of the attachment portion
doesn't match
The Push button is positioned
halfway
The trigger switch is being pulled only
slightly.
Attempting to install a battery other
than that specified for the tool.
15
Remedy
Get rid of the problem causing the
overburden.
Let the battery cool down.
This is not a malfunction.
The motor was automatically stopped
to prevent failure of the tool.
Be sure to use 12.7 mm square drive
sockets.
Press the button firmly into position
for the desired direction of rotation.
This is not a malfunction.
It does not occur if the trigger switch
is pulled more fully.
Please install a multi volt type battery.