Jafar 4499 Bedienings- en onderhoudshandleiding - Pagina 10
Blader online of download pdf Bedienings- en onderhoudshandleiding voor {categorie_naam} Jafar 4499. Jafar 4499 10 pagina's. Return butterfly valves double eccentric
4. ASSEMBLY AND INSTALLATION
Due to irregularities of the velocity and pressure observed near the curvature or T-piece, it is
recommended, as long as conditions at the designed device allow it, that the distance of the bend or T-piece,
located upstream or downstream the butterfly valve, to the rabbet surface be no less than 5 times Dnom.
Generally, it is recommended avoiding butterfly valves near bends, T-pieces and curvatures at large.
4.2 ASSEMBLY INSTRUCTIONS
Before installing the fittings, check the technical and commercial documentation, i.e. application of
media and operation parameters of the pipeline in which they are to be installed. Any change in the operating
conditions must be consulted with the fitting's manufacturer.
Before the assembly works, remove the sealing of the main pass, if any; check the condition of the inner
surfaces of the butterfly valve and, if necessary, carefully wash them with water.
Before the assembly of fittings between pipeline flanges, remove maintenance agents applied as the
protection of surfaces during transport. Carefully cleanse flange rabbets. Mount previously prepared seals and
tighten the entire unit with sufficiently long bolts connecting two neighbouring pipeline flanges. The value of the
torque to be applied to the bolt nut is specified in PN-63/M-82056.
Note! If the product is damaged mechanically, do not install it in the pipeline.
The installation and design of the valve is shown in the following figure:
1.- butterfly valve, 2.- nut, 3.- pipeline flange, 4.- washer, 5.- fixing bolt, 6.- flange seal
4.2 OPERATION
Butterfly valves should be operated according to requirements pertaining to connection fittings. Exceeding
the operating limits of the fitting may result in damage that will not be covered by the warranty granted by the
manufacturer.
4.3 OH&S REGULATIONS
Butterfly valves are subject to guidelines and recommendations included in H&S regulations applicable
to the installation of pipelines and equipment in: water supply stations, thermal power stations, sewage treatment
plants, intermediate pumping stations and other structures, as well as general health and safety regulations (use of
upper limb protection equipment, lower limb protection equipment, head protection equipment and protective
clothing), in particular during works with low and high temperature exposure.
Misuse of the products is prohibited.
5 GUARANTEE CONDITIONS
The manufacturer grants guarantee for the product being installed and operated according to this O&MM. The
conditions and period of the guarantee are specified in the guarantee sheet.
OPERATION AND MAINTENANCE MANUAL
01-2016
10