MIEN2016/2018/2024/2026 Rack Mount Industrial Ethernet Switch
Figure 2-9.
Figure 2-9 ICMP setting interface diagram
Then click Start→Run of test computer 1, enter cmd or command (cmd for
Win2000/XP system, command for WIN98/95 system), a console window will
pop up, and send ping 192.168.0.11 –l 1000 –t, (–l It refers to the number of
bytes to send data packets, -t refers to continuously sending data), run ping
192.168.0.10 -l 1000 -t in test computer 2 in the same way. If test computer 1
returns Reply from 192.168.0.11: bytes=1000 time<10ms TTL=128, test
computer 2 returns Reply from 192.168.0.10: bytes=1000 time<10ms TTL=128,
use CTL+ after running for more than 10 minutes The C command statistics
packet loss rate is 0, indicating that the device is working normally. As shown in
Figure 2-10.
Figure 2-10 The result of inputting the ping test computer in CMD
- 11 -