Hardware Installation

4

Installation Precautions

To prevent equipment damage or personal injury caused by improper use,
observe the following precautions:
During the installation process, you need to wear anti-static gloves or
anti-static gloves, and power-off the switch.
Please make sure that the input voltage is within the input voltage range
marked on the switch.
The transmission distance has a certain relationship with the connected
wire. It is recommended to use a standard Cat5e/6 network cable.
The equipment must be grounded for lightning protection, otherwise the
protection level of the equipment will be greatly reduced; please use a
wire of No.20 or more to connect the grounding terminal to the ground.
The power line, ground line and signal line are laid out separately and the
distance is not less than 5cm.
[Device installation]
Install rack-mounted equipment
Rack-mounted installation, the installation steps are as follows:
Step 1 Select the installation location of the device and make sure it has
sufficient size.
Step 2 Use 2 screws to install the mounting ear to the position of the
device as shown in the figure below.
Step 3 Put the device on the rack, and use 4 screws to fix the left and
right side brackets to the rack respectively.
Step 4 Check and confirm that the product is securely installed on the
rack, and the installation is complete.
[Device connection]
Step 1 Connect one end of the ground wire to a suitable position, and fix
the ground plate on the switch panel with washers and screws.
Step 2 Connect the power cord to the switch's power terminals.
Step 3 Connect the network cable to the RJ45 port of the switch.
Step 4 Insert the SFP optical module into the SFP port and connect the
fiber-to-fiber transceiver.