Electrical Requirements

The shower must only be connected to a
230/240V AC electrical supply, from a 13-amp
ring main; via a fused double pole switch with
at least 3mm contact separation.
A manual switch is to be clearly identifiable,
with a minimum distance of 2.5m from a fixed
tap or shower, i.e. mounted in an adjacent
room or via a ceiling-type pull cord.
It should be fused at no more than 3 amps.
This appliance must be earthed, and all
associated metal pipe work earth crossbonded
in line with current I.E.E. regulations.
Please use the cable entry point provided.
Failure to comply will eliminate any BEAB
approval.
As the colours of the wires in the cable (not
supplied) used to connect to this appliance
may not correspond with the coloured
markings identifying the terminals in your
switch, please follow the procedure below:
• The wire, which is coloured Blue or
Black, must be connected to the terminal
that is marked with the letter N.
• The wire, which is coloured Brown or
Red, must be connected to the terminal that
is marked with the letter L.
• The wire, which is coloured Green or
Yellow, must be connected to the terminal
that is marked with the earth symbol
• The installation and wiring must comply
with I.E.E regulations.
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Mains
Water
Supply
Fused
Spur
.
Mains
Electric
Supply
Cold Water
Storage Tank
1m Minimum
Isolating
Hot
Water
Storage
Tank
Minimum
2.5m
Manual
Switch
Minimum
25mm
between
Shower head
and spillover
Typical Power Shower Installation
Valves
1m
5