Before setting out the front in-line panel you will have to
1
determine how much you will need to cut off the front in-line
panel A and horizontal return profile. If you cut off 9mm from the
square end of the profiles then the glass panels will sit in the
centre of the vertical wall profile adjustment.
A
A
Before cutting the horizontal profiles, you will also have to
3
consider whether the walls that the panels will be fixed to are
leaning in or out.
A: If wall leans in at top: leave extra length on the profile; cut
off less than 9mm.
B: If wall leans out at the top;the profile needs to be shorter;
cut off more than 9mm.
(Return profile)
B
B
C
C
The Majestic Shower Company Limited
One North Place, Edinburgh Way, Harlow Essex
CM20 2SL England,
Wall
Profile
(5 mm) (5 mm)
Floor profile
If you cut 9mm off the square end of the profiles, then the
2
glass panels will sit in the centre of the vertical wall profile
adjustment. Before cutting the horizontal profiles make sure
the front glass in-line panel and return panel will fit into their
floor profiles after you have cut off the amount. The horizontal
profiles are mitred as a guide but supplied at maximum
adjustment length.
It is likely you will have to cut them down.
(In-line profile A)
(Door panel B)
If the unit is being installed on a tray the position of the profiles
4
in relation to the lip of the tray must also be considered. Ideally
the outer edge of the profiles should sit 10mm back from the
front edge of the tray.