Troubleshooting

Symptom
No flow or poor flow
rate.
Water dripping for a few
seconds after the tap
has turned off.
Constant dripping for a
few seconds after the
tap has been turned off.
Fitting does not turn on.
Water does not come
out of the showerhead
when using the bath
shower mixer.
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
Cause
Partially closed stop or service
valve in water supply pipework to
the tap.
Head of water is below the
minimum distance required.
Possible airlock/ blockage in
supply pipework
Cartridge not opening fully.
This is caused by 'capillary action'
and residual water in the spout
being siphoned out. This should
only last for a couple seconds
Cartridge/ Valve not fully
shutting off.
Water supplies not turned on.
Closed stop or service valve.
Diverter mechanism not fully
open.
Insufficient water pressure/
header height.
Remedy
Open stop or service valve.
Refer to the specification
section for minimum pressures
required.
Remove water supplies from
the fitting and flush the system
to remove any airlocks/debris
Service fitting. Refer to
maintenance section.
Service fitting and
replace cartridge. Refer to
maintenance section.
Check that the water supplies
to the fitting a re turned on.
Open stop or service valve.
Turn the diverter mechanism
into the appropriate position.
Refer to the specification
section for minimum pressures
required.
15