Maintenance

Replace/Clean Cartridge:
Sequential Shower Valves:
Undo the grub screw to
1
remove the handle. This can
be located at the top or underneath
the handle. Unscrew the cartridge
shroud if necessary.
3
Remove all seals and check for any
damage. Place the cartridge in a
suitable solution and soak until fully
de-scaled. Rinse thoroughly.
Replace all seals and grease
with a WRAS approved sealant.
14 Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.
2
Use a 30mm socket spanner to unscrew
the cartridge from the valve body.
Carefully remove the cartridge and spring.
IMPORTANT
Isolate the
water supply
before starting!
4
Reset the maximum temperature.
Reverse the steps to re-fit
the cartridge and handle.