Majestic fireplaces ODGSR36ARP Installatie- en bedieningshandleiding voor huiseigenaren - Pagina 5

Blader online of download pdf Installatie- en bedieningshandleiding voor huiseigenaren voor {categorie_naam} Majestic fireplaces ODGSR36ARP. Majestic fireplaces ODGSR36ARP 20 pagina's. Outdoor gas fireplace

Majestic fireplaces ODGSR36ARP Installatie- en bedieningshandleiding voor huiseigenaren

Moisture Resistance

This outdoor fireplace will shed moderate amounts of
water, but is not waterproof. Water and condensing wa-
ter vapor may enter the chase under certain conditions.
The fireplace will not perform as an exterior wall. Mois-
ture penetration must be considered for construction
that places the fireplace in structure walls or on mois-
ture sensitive surfaces.
When installed on exterior walls: CFM Corporation
recommends the fireplace chase be constructed outside
the structure's weather envelope. Where the platform
meets the wall, use a flashing detail similar to that
required for attached decks. Chase platforms, including
hearths should slope away from the structure at 1/4 in
per foot. The fireplace can be shimmed level.
When installed on surfaces where water may collect or
cause damage: CFM Corporation recommends a slope
of 1/8 in to 1/4 in per foot towards the drain port sug-
gested. The fireplace can be shimmed level.
Hearths should slope away from the front of the fire-
place and chase at 1/8 in to 1/4 in per foot. Metal safety
strips must be on top of any combustible hearth materi-
als used for moisture management.

Screened Porch Installation

The ODGSR may be installed safely and is design
certified by CSA to be installed in a screened porch with
these guidelines:
Minimum porch area ..............................96 sq. feet (9 sq m)
Minimum celing height ..................................... 92" (234 cm)
Minimum of two (2) walls must be screened
Minimum top of screen height, side walls ........6'6" (198 cm)
Minimum screen area ............................64 sq. feet (6 sq m)

Clearance to Combustibles

Appliances
Top ..........................................................0" (0 mm)
Bottom .....................................................0" (0 mm)
Side .........................................................0" (0 mm)
Back ........................................................0" (0 mm)
Perpendicular Sidewall ...........................0" (0 mm)
Top of unit to ceiling ..........................36" (914 mm)
Front of unit to combustibles .............36" (914 mm)
20007114
ODGSR Series Outdoor Gas Fireplace

Mantels

WARNING: A 4" hood must be used if a
mantel is to be installed.
The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
For the correct mounting height and widths refer to
Figures 3a and 3b
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
When using paint or lacquer to finish the
mantel, such paint or lacquer must be heat
resistant to prevent discoloration.
Side View
Maintain minimum
3/4" (19 mm)
clearance to
combustible.
A
B
Ref.
Mantel
Shelf Depth
CFM146
Y
8" (203 mm)
DV Mantel Chart
Z
1¹⁄₂" (38 mm)
7/5/01 sta
Fig. 3a Mantel clearances.

Hearth

A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth.
Y
Z
Standoff
Fireplace
Top of Combustion
Chamber
CFM146
Ref.
Mantel From Top
of Comb. Chamber
A
28"
(711 mm)
B
26"
(660 mm)
5