Green BM200 Series Gebruikershandleiding - Pagina 5
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Green BM200 Series. Green BM200 Series 19 pagina's. Battery tester charger discharge maintainer
Note: Following examples are all based on BM200-05 @ 3.2V100Ah LiFePO4 battery.
3.Set Battery Parameter:
3.1 select [1. Set battery param]
[Battery type]: Select of one from LiFePO4, Li-Ion, Pb-Acid, NIMH, NICD,
[Battery voltage]: Select battery nominal voltage from 2.0V ~ 28.8V, marked on battery label.
[Battery capacity]: Input the Ah value of battery capacity, which is marked on battery label.
[Charge voltage]: Charge voltage limit during charging process, marked on battery label.
[Charge current]: Set a constant current for charging process, recommend is 0.1C~0.5C.
[Battery in-resist]: Set the battery internal resistance, which is listed on battery datasheet.
[Dischar current]: Set a constant current for discharge process, recommend is 0.1C~0.5C.
[Dischar cut-off]: Set cut-off voltage for discharge process. Recommend is 0.8*rating voltage.
SHENZHEN GREEN DIGITAL POWER TECH CO., LTD
BM200 can be used for many types batteries. To get the accuracy test
results and charge safety, at first you should set the connected battery
parameters. If the battery connected is the same as last time, please
refer to Clause 3.2; Otherwise, please execute the following
(When the background of this item is highlighted, it means
selected, the same below), press <Enter> Key,screen will be:
Battery type
Battery voltage :
Battery capacity : 100 Ah
Charge voltage :
Charge current :
Battery in-resist :
Dischar current :
Dischar cut-off :
Save
This step can be skipped, BM200 will auto set a good default data.
This step can be skipped, BM200 will auto set a good default data.
This data is only used for evaluate battery SOH. If you have no data,
this step can be skipped, BM200 will auto set a genaral default data.
This step can be skipped, BM200 will auto set a good default data.
This step can be skipped, BM200 will auto set a good default data.
:
LiFePO4
3.2
V
3.65 V
20.0 A
mΩ
5
20.0 A
2.60 V
Return
5