Green GPM-312-A Gebruiksaanwijzing

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Green GPM-312-A. Green GPM-312-A 2 pagina's.

Wiring diagram
Front panel
INPUT PULSE
RELAY
SET
GREEN
GPM - 312A
COUNTER
Dimensions
External dimensions
INPUT PULSE
RELAY
48
SET
GREEN
GPM - 312A
COUNTER
96
10
SPECIFICATIONS
Range
Display
Reset
Input
Pulse frequency
Special feature
Indications
Set points
Output
Relay contact rating
(Resistive load)
Mechanical life of relay
Electrical life of relay
User programming
Count direction
Power consumption
Supply voltage
Operating voltage range
Weight
Dimension ( L x W x D)
Ambient humidity
Ambient temperature
Storage temperature
In the pack
Rear panel - Connection diagram
PROXIMITY
PNP
MAIN RLY
O / P
1
3
4
2
5
6
7
8
NO
C
NC
SENSOR
24 VDC
RESET
E
P
N
NC
C
NO
9
10
11
12
13
14
15
16
85 - 265 V AC, 50HZ
SUPPLY
Panel cutout dimensions
45
90
75
All dimensions are in mm
999 999 Counts
Six digits, 0.4 Inch seven segment LED
Manual, Remote
PNP Proximity unit
30 Hz
Memory Retension
Input Pulse and Relay
Three (Main Count, Batch Count, Time)
Two relay, 1 c/o
10 A @ 230 VAC
/ 30 VDC
10 million operation
100.000 operation
3 Keys & Displays
Up
5 VA
24V AC, 50HZ
+ / -10% from the rated voltage
170 grams
96 x 48 x 75
35 to 85 % RH
-10 to 55 c
-25 to 65 c
counter, side clamp and instruction manual
GPM - 312-A
COUNTER
INSTRUCTION MANUAL
Introduction
Thank you very much for purchasing this GREEN product GPM - 312-A.
Please read the instruction manual carefully for the full usage of this product
The counter has passed various quality tests before despatch. Please check however,
at the time of arrival, its model code and its appearance and ensure that all the contents
are provided and there are no faults, damage etc, to the counter. Please also ensure that
the model code ,which is labeled on the counter, is identical to the one you ordered.
Note :
1. Our company shall not be liable for any damages, as described below, caused to both
any users and third parties
a) Damages caused by the result of operation of the product.
b) Damages caused by any defects in the product which are unpredictable for us.
2. The content in this manual are subject to change without any notice. If you have any
suggestion on the matter, Please do not hesitate to contact us.
Precaution for safe use
(1) Use and store the Counter within the specified ambient temperature and humidity
ranges.
(2) Do not use the product in location subject to vibrations or shocks. Using the product
in such location over a long period may result in damage due to stress.
(3) Do not use the product in locations subject to dust, corrosive gases, or direct sunlight
(4) Separate the input signal devices, input signal cables and the product from the source
of noise or high - tension cables producing noise.
(5) The supplied power voltage and load must be within the rated and specified ranges.
.
(6) Do not use where the water or oil splatter on the counter
(7) Install a switch or circuit breaker that allows the operator to immediately turn off the
power
Manufacturer
GREEN MICROELECTRONICS INDIA PVT. LTD.
100 Taskant street, B.R. Puram, Peelamedu,
Coimbatore - 641004.Phone no : 0422 4218101
e
- mail : greenmicroelectronics@airtel
GREEN
COMPONENTS FOR AUTOMATION
mail
.in
- www.greenelectronics.in
TM