Green Brook KingShield TXPIR120W Installatie-instructies

Blader online of download pdf Installatie-instructies voor {categorie_naam} Green Brook KingShield TXPIR120W. Green Brook KingShield TXPIR120W 2 pagina's. Xenon floodlights with pir

Installation Instructions
For Xenon Floodlights with PIR
Model Ref: TXPIR120 (Black)
& TXPIR120W (White)
This unit should be installed by a competent
person in accordance with the current IEE
Wiring Regulations. If in doubt consult
a qualified electrician.
INSTALLER - PLEASE READ THIS
INSTRUCTION MANUAL
BEFORE INSTALLING THE UNIT
This floodlight is provided with an
infrared detector. The detector senses
'warmth movement' in the surrounding
area and when it is dark. When movement
is detected the lamp will come on. This
fitting has no manual override.
INSTALLATION
Switch the power off before installation
to prevent electric shock.
NOTE 1.
On installation try not to install light
fitting close to a vent such as a vent
from a boiler or tumble dryer as hot
air movement can cause the lamp to
switch on when it is not required to.
NOTE 2.
Passing cars (warm engines) and
nearby trees and bushes can cause
your lamp to switch on, due to a
sudden change in temperature and
gusts of wind. Please bear this in
mind when deciding on where to
install your light.
NOTE 3.
Do not mount the fitting in the ceiling.
NOTE 4.
Please ensure the distance between
the front glass of the lamp and the
surface area the lamp is lighting is at
least 1 metre apart.
1. The lamp fitting can be installed using
the three holes on the mounting
bracket. The bracket should be
horizontally fixed. See Fig.2.
2. Loosen the supporter bolts to adjust
the installation angle of the lamp in
accordance with the lighting direction
needed. The lighting direction cannot
be adjusted downwards more than
°
45
, see Fig.2.
ELECTRICAL WIRING
Open the terminal box cover and
unscrew the inlet gland and remove
the sealing ring. Thread the power
cable through the inlet gland and the
sealing ring.
Live = Brown/Red
Neutral = Blue/Black
Earth = Green and Yellow
Insert the wire ends into the terminal
block and then tighten them. Replace
the box cover, screw in the inlet
gland together with the sealing ring.
INSTALLING THE LAMP TUBE
1. Unscrew the bolt and open the glass
holder. Fit the tube into the tube
socket. Keep the waterproof rubber
pad in its original position and close
the glass holder with the bolt.
2. When replacing the lamp - isolate
the fitting from the supply before
opening the glass front. If the lamp
was recently turned off do not touch
the lamp tube with bare hands.
Please follow lamp manufacturers
instructions when fitting the lamp.
3. If glass cover becomes cracked,
replace immediately before using the
lamp again.
OPERATION
The infrared detector is equipped with
two adjusting controls, see Fig.3. below.
Time Control
The time adjustment control adjusts
the lighting period of the lamp after the
detection of movement. This period is
adjustable from 9 secs to 10 mins. Turn
the control clockwise to increase the
lighting period and anti-clockwise to
reduce the lighting period.
Fig. 1
Fig. 2
Fig. 3