Major tech MT 770 Gebruiksaanwijzing - Pagina 14

Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Major tech MT 770. Major tech MT 770 20 pagina's. Clamp meter
Ook voor Major tech MT 770: Gebruiksaanwijzing (16 pagina's)

Major tech MT 770 Gebruiksaanwijzing

11. DUTY CYCLE MEASUREMENT

Duty Cycle (or Duty Factor) is the percentage of time a
signal is above or below a trigger level during one cycle.
The Duty Cycle mode is optimized for measuring the On
or OFF time of logic and switching circuits. Systems
such as electronic fuel injection systems and switching
power supplies are controlled by pulses of varying
width, which can be checked by measuring the Duty
Cycle.
1. Set the function switch to
The meter automatically defaults to Frequency
range.
2. Press the
Cycle range. The meter automatically defaults
to Resistance.
3. Insert the red test lead into the "V Ω ºC ºF HZ"
input terminal and the black lead to the "COM"
terminal.
4. Connect the other end of the test leads to the
circuit or component under test. Take the
reading on the display.
Note: • In the Duty Cycle range the meter is Auto
Ranging only.
a
Duty Cycle : % duty =
13
Hz •
%
button to select the Duty
b
Hz •
%
range position.
a
__
x 100
b