Centurion D5-EVO REPAIR Handleiding voor installatie-instructies - Pagina 13
Blader online of download pdf Handleiding voor installatie-instructies voor {categorie_naam} Centurion D5-EVO REPAIR. Centurion D5-EVO REPAIR 14 pagina's. Sliding gate operator
Ook voor Centurion D5-EVO REPAIR: Configuratiehandleiding (13 pagina's), Handleiding voor programmering (4 pagina's)
Mounting the origin marker (continued)
13. Manually slide the gate
OPEN until the origin
marker is in line with the
origin sensor.
14. Ensure distance between
face of marker and front
face of sensor is between
13 and 20mm.
Take care with the
orientation of the arrow on
the origin marker. This
arrow must face the
operator
15. Adjust distance by sliding
the origin marker along the
slotted mounting holes
until the specified distance
is achieved.
For best results keep gap
between marker and
sensor as small as
possible
It is possible to make the distance between the marker and the
sensor much greater than 500mm. However, if using the
pedestrian opening facility, although the position of the marker
will not affect the width of the pedestrian opening, it is
preferable to have the marker mounted inside of the pedestrian
opening point