Centurion R3R5 Handleiding voor snelle installatie - Pagina 3

Blader online of download pdf Handleiding voor snelle installatie voor {categorie_naam} Centurion R3R5. Centurion R3R5 17 pagina's. Rotary swing gate operator

S
TANDARD
Gate Opening
Angle (Degrees)
60
70
80
90
100
110
120
Figure 2 Standard Pedestal Mount Installation
P
EDESTAL

Pedestal Mount

Installation
H
H
B
0
750
90
750
130
750
220
700
355
700
570
600
605
450
M
OUNT
Gate Bracket
GATE LEAF IN CLOSED POSITION
C
Gate Bracket
700
700
700
700
650
610
570
C
B E S U R E T O U S E A L O N G
C O N N E C T I N G A R M F O R T H I S
INSTALLATION TYPE.
 Ensure that the gate does not exceed the
relevant specifications (IM page 9)
 Only recommended values are provided. For
variances, refer to the Installation Manual.
 All dimensions shown are indicated in millimetres.
 All recommended values will result in gates with
similar opening times.