10
S
ET THE
Loosen the connecting arm slightly and move it to its fully retracted position.
Open the gate ½ way.
Assemble the connecting arm to the gate bracket.
Now slowly push the gate to its closed position. (The drive arm will turn, and
the connecting arm will extend while doing so)
Check that the hinge points of the gate bracket, connecting arm and motor
output shaft are in a straight line as shown in Figure 8.
Carefully unhook the connecting arm from the gate bracket and tighten
lightly.
Check the gate opens and closes sufficiently by manually operating the
gate.
IF THE GATE OPENS TOO LITTLE
Lengthen the drivearm by 10 mm and readjust the connecting arm.
IF THE GATE OPENS TOO MUCH
Shorten the drivearm by 10 mm and readjust the connecting arm.
Fully tighten connecting arm.
Apply the warning decals supplied to either side of the gate frame.
A
LIGNMENT OF
Figure 8 Align Gates
10
C
ONNECTING
H
P
INGE
OINTS
GATE LEAF IN CLOSED POSITION
A
L
RM
ENGTH
NB. Hinge points must be in a