Major tech MT800 Gebruiksaanwijzing - Pagina 5
Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Major tech MT800. Major tech MT800 8 pagina's. Analogue multimeter
WARNING: Use with extreme caution. Follow all safe guards suggested
in the manual in addition to normal safety precautions. Do not use this
meter if you are unfamiliar with electrical circuits and testing procedures.
4. TIPS FOR USING YOUR MULTIMETER
When using this tester, pay particular attention to polarities and check
positive and negative points. The red lead connects to positive points and
the black lead to negative. If you are checking unknown voltage and
currents, use highest range first then next lower range, and so on until
readings can be obtained. For most accurate readings, keep the meter lying
flat. Also, use a range setting that results in a reading in the upper third of
the meter scale. For exact readings, look at the scale from the point where
the pointer and its reflection on the mirror come together, otherwise a
reading error may result due to parallax.
5. TEST LEADS
Only use the same type of test leads that are supplied with this meter.
These test leads are rated for 1000V.
6. BATTERY INSTALLATION
A battery is required for resistance measurements. To install, use a phillips
screwdriver to remove the screw on the back cover. Pull apart the front and
back covers. Insert 1 AA battery (not supplied) in the battery compartment
observing correct polarity. Never leave a weak or dead battery in your unit.
Even leak-proof types may leak damaging chemicals. Remove the battery
when you don't intend to use your unit for more than a week.
To avoid electric shock, disconnect measuring terminals before installing
or removing battery. Open cover only when replacing battery, do not
touch any inside area other than the battery.
7. OPERATION
CAUTION: the MAX input limit for voltage and current measurements
between '+' and '-' is 500V AC, 500V DC and 250 mA DC.