Oven Installed in Cabinet
F
_A
B
C
A. 24" (61 cm) min. cabinet width
B. 1" (2.5 cm) top of cutout to bottom
of upper cabinet door
C. 32" (81.3 cm) bottom of cutout to
floor
D. 22" (56 cm) cutout width
E. 11/2 '' (3.8 cm) min. bottom of
cutout to top of cabinet door
F. 23½2" (58.5 cm) min. cutout
height
Cabinet Side View
........
f
D
fC
A. 231/4'' (59.1 cm) min. cutout depth
D. Recessed oven
B. 23" (58.4 cm) recessed oven depth
E. Cabinet
C. Qven front
If codes permit and a separate ground wire is used, it is
recommended
that a qualified electrical installer determine that
the ground path and wire gauge are in accordance
with local
codes.
Check with a qualified electrical installer if you are not sure the
oven is properly grounded.
This oven must be connected to a grounded metal, permanent
wiring system.
Be sure that the electrical connection and wire size are adequate
and in conformance
with the National Electrical Code, ANSI/
NFPA 70-latest edition or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No. O-M91-1atest edition, and
all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch
Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Electrical
Connection
To properly install your oven, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
Oven must be connected to the proper electrical voltage and
frequency as specified on the model/serial
number rating
plate. The model/serial
number rating plate is located at the
bottom of the right-hand mounting rail. See the following
illustration.
Single Oven
A. Model/serial
number plate
Models rated at 7.2 kW and below at 240 volts (5.4 kW and
below at 208 volts) require a separate 30-amp circuit.
A circuit breaker is recommended.
Connect directly to the circuit breaker box (or fused
disconnect) through flexible, armored or nonmetallic
sheathed, copper cable (with grounding wire). See "Make
Electrical Connection"
section.
Flexible conduit from oven should be connected directly to
the junction box.
Do not cut the conduit. The length of conduit provided is for
serviceability of the oven.
A UL listed or CSA approved conduit connector must be
provided.
If the house has aluminum wiring follow the procedure below:
1. Connect a section of solid copper wire to the ends of the
flexible conduit leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors
and/or tools
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's
recommended
procedure. Aluminum/copper
connection must conform with
local codes and industry accepted wiring practices.