If the cable from appliance is equipped with 4 wires:
Where local codes permit connecting the
appliance-grounding conductor (wire) to the
neutral (white) wire (see figure 5):
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box,
connect appliance and power supply cable wires
as shown in figure 5.
Cable from Power Supply
White Wire
(Neutral)
Red
Wires
Ground Wire
(Bare or
Green Wire)
Cable from appliance
3-WIRE GROUNDED JUNCTION BOX
WARNING!
This appliance is manufactured with a
white neutral power supply and a frame
connected copper wire. The frame is
grounded by connection of grounding lead
to neutral lead at the termination of the
conduit, if used in USA, in a new branch
circuit installation (1996 NEC), mobile
home, recreational vehicles, where local
code do not permit grounding through
the neutral (white) wire or in Canada,
disconnect the white and green lead
from each other and use ground lead
to ground unit in accordance with local
codes, connect neutral lead to branch
circuit-neutral conductor in usual manner
see Figure 6. If your appliance is to be
connected to a 3 wire grounded junction
box (US only), where local code permit
connecting the appliance-grounding
conductor to the neutral (white) see
Figure 5.
Black
Wires
Junction
Box
White Wire
(Neutral)
U.L.-Listed Conduit
Connector (or CSA listed)
Figure 5
If cooktop is used in a new branch circuit
installation (1996 NEC), mobile home,
recreational vehicle, or where local codes do
not permit grounding through the neutral
(white) wire (see figure 6):
1. Disconnect the power supply.
2. Separate the green (or bare copper) and white
appliance cable wires.
3. In the circuit breaker, fuse box or junction
box:connect appliance and power supply cable
wires as shown in figure 6.
Cable from Power Supply
Ground
Wire
Red
Wires
Ground Wire
(Bare or
Green Wire)
Junction Box
Cable from appliance
4-WIRE GROUNDED JUNCTION BOX
WARNING!
If connecting to a 4-wire power supply
cable electrical system, the appliance
frame connected ground wire MUST NOT be
connected to the neutral wire of the 4-wire
electrical system.
NOTE TO ELECTRICIAN: The armored cable
leads supplied with the appliance are UL and CSA-
recognized for connection to larger gauge household
wiring. The insulation of the leads is rated at
temperatures much higher than temperature rating
of household wiring. The current carrying capacity
of the conductor is governed by the temperature
rating of the insulation around the wire, rather than
the wire gauge alone.
White
Wires
Black
Wires
U.L.-Listed Conduit
Connector (or CSA listed)
Figure 6