7.1 Maintenance
Only undertake the maintenance works under the observance of all relevant safety
precautions, the filter is contaminated!
7.2 Daily maintenance
Check hoses on tightness and continuous flow
Visual check if pre filters are dirty
7.3 Filter change
Attention:
Filter change:
The suction hoses, pumps, filter housings and filter are contaminated after the first
use. Repairs and maintenance have to be executed only under the observance of
all relevant safety measures. All the filters mentioned have to be disposed of
according to the legal terms.
Instruction manual
Water treatment boiler system D 110 L
7 Maintenance and care
Filter change only if the device is switched off
Demount dirty filters only in wet shape to avoid contamination
Use only approved filters
It is prohibited to use damaged filter candles
Loose the nut
Take out the filter and dispose of it
Insert the new filter candles
Tighten the nut