Make Electrical Connection
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box and install
a UL listed or CSA approved
4. Run home power supply wiring through
into terminal box.
E
D
C
B
A
A UL listed wire connectors
B. White wires
C. Black wires
D. Green (or bare) wire connected to yellow-green wires
E. Home power supply
5. Use UL listed wire connectors and connect white
wires (B) together.
6. Use UL listed wire connectors and connect black
wires (C) together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect green (or bare) ground wire from home power
supply to the 2 yellow-green ground wires (D) in terminal
box using UL listed wire connectors.
10
/
" strain relief.
1
2
/
" strain relief
1
2
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Reconnect power.
Install Vent Covers
NOTE: Remove protective film from the vent covers.
When using both upper and lower vent covers, push lower
cover down onto hood, and lift upper cover to ceiling and
install with (2) 2.9 x 6.5 mm (Phillips) screws.
D
C
A. Upper vent cover
B. Lower vent cover
C. 2.9 x 6.5 mm screws
D. Bracket
NOTE: For vented installations, the upper vent cover
may be reversed to hide slots.
Complete Installation
1. For non-vented (recirculating) installations only, install
charcoal filters over the grease filters using the clips
provided in the kit. See the "Range Hood Care" section.
2. Install metal filters. See the "Range Hood Care" section.
3. Check the operation of the range hood blower and light.
See the "Range Hood Use" section.
NOTE: To get the most efficient use from your new range hood,
read the "Range Hood Use" section.
C
A
B