Place the lower support bracket on the template aligning it
with the traced rectangle. Mark centers of 3 fastener
locations through the template to the wall.
IMPORTANT: All screws must be installed into wood.
Remove the template.
9. Drill %4" (2.75 mm) pilot holes at 2 upper locations where
screws are being installed into wood.
10. Attach the lower support bracket to the wall using
2 - 5 x 35 mm screws at location marked on the template.
A
A. Lower support bracket
B. Centerline on wall
C. 5 x 35 mm screws
Vent Cover
Bracket Assembly and Installation
1,
Assemble the 3 pieces of the vent cover bracket using 4 -
4 x 8 mm screws provided. The assembled bracket should be
sized to fit inside the upper vent cover.
\
J
J
2=
A. Vent cover bracket assembly
B. Upper vent cover
C. 4 x 8 mm screws
D. Adjustable width
Install vent cover bracket to wall about 1/8"(3 mm) away from
the ceiling with 2 - 6 x 70 mm screws and 2 - 10 x 70 drywall
anchors supplied.
i
i
............
A
i ..............................
g
I
A. Vent cover bracket
B. Centerline on wall
Complete Preparation
1. Determine and make all necessary cuts in the wall for the vent
system. Install the vent system before installing the hood. See
"Venting Requirements" section.
2. Determine the required height for the 1/2"conduit and drill a
11¼"(3.2 cm) hole at this location.
3. Run wire through the home power supply cable according to
the National Electrical Code or CSA Standards and local
codes and ordinances. There must be enough 1/2"conduit
and wires from the fused disconnect
(or circuit breaker) box
to make the connection
in the hood's electrical terminal box.
4. Use caulk to seal all openings.
NOTE: Do not reconnect power until installation is complete.
1,
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
Using 2 or more people, hang blower housing on the lower
support bracket using the 2 mounting hooks on the rear of
the blower housing.
E
A. Lower support bracket
B. Mounting hooks
C. Adjust side to side.
D. Adjust up and down.
E. Blower housing
2. Level the blower housing with leveling screws in mounting
hooks, using a level across bottom of blower housing.
3. Remove the metal grease filter and secure the blower
housing with one screw in the bottom hole located in the rear
of the blower.
\
A. Rear of blower housing
B. Bottom 5 x 35 screw hole