Attaching to a 4S junction box
Be sure to use the adapter ring to attach the camera body when embedding it in
the 4S junction box.
1
Attaching the adapter ring
Attach the adapter ring to the 4S junction box.
Please use screws that are suitable for the 4S
junction box.
Do not tighten the screws to the extent that the adapter
ring is bent.
2
Attaching the camera body
1 Remove the surface mount cover from the cam-
era body.
2 Remove the body cover, Attach the camera body
to the adapter ring.
Please use the self-tapping screws included. Do
not use any other screws.
Connecting the cables
Connect the power cable.
1
While using 12 V DC, connect the positive (+) side to "+12 V DC."
12V DC connection
Be sure to check that the cables are connected correctly before turning the power on.
Turning on the power when the cables are connected with incorrect polarity may dam-
age the camera.
While using 24 V AC, use power supply marked "Class 2."
2
Connect the video cable running from the monitor to the video relay
cable.
Connect the video cable running from the monitor to the video relay cable attached
to the camera body.
EG-7
24V AC connection
Connect the video cable
from the monitor here.