__... grate
burner cap
knob
burner
burnerbox
Install the pressure regulator with the
arrow on the regulator pointing up
toward unit and in a position where
you can reach the access cap.
Lift entire cooktop up from cutout when
repositioning
cooktop in countertop opening
to prevent scratching
countertop,
[_
Insert cooktop into countertop opening.
Center the cooktop in the cutout. Check
that front edge of cooktop is parallel to
front edge of countertop. Check that all
required clearances are met. Use a pencil to
outline the rear of the cooktop on the countertop.
Remove the cooktop from the cutout and place
upside down on a protected surface.
so each is
Attach the mounting brackets to each
side of the burner box with the 5/16"
(0.80cm) screws. Do Not tighten the
screws. Turn the mounting brackets
under the burner box.
]_
einsert the cooktop into countertop
opening. Check that cooktop is
parallel to front edge of countertop.
Lift entire cooktop to make
adjustments so the foam sealing strip can seal
properly.
Fire Hazard
Do Not make connection too tight. The
regulator is die cast,
Overtightening
may crack regulator
resulting in a gas leak and possible fire or
explosion,
3/8" (0.95cm) nipple flexible connector 3/8" (0.95cm) nipple
3/8" (0.95cm) adapters
/
!
manual shutoff valve
pressure
regulator
All connections must be wrench-tightened.
Assemble the flexible connector
from the gas supply pipe to the
•
pressure regulator in order:
manual shutoff valve, 3/8"
(0.95cm) nipple, 3/8" (0.95cm) adapter, flexible
connector, 3/8" (0.95cm adapter, and 3/8"
(0.95cm) nipple.
I1
0
I Use pipe'j°int
c°mp°und
made
f°r
use with NATURAL and L.P. gas
•
to seal all gas connections. If
flexible connectors are used, be
certain connectors are not kinked.
Injury Hazard
Do Not overtighten
screws.
Overtightening
screws could cause
personal injury.
glass cooktop
countertop
c,a% n'g4Cm)
_,,,
screw
/\
=..:,
mounting
5/16" (0.80cm)
bracket
clamp bracket screw
Rotate mounting brackets away from
burner box. Tighten the mounting
brackets to the burner box. Insert the
2-1/2" (6.4cm) clamping screws into
the mounting brackets. Use a screwdriver to
tighten screws against the underside of
countertop.
shutoff valve
to cookto_
to gas
supply line
1
Open
the shutoff valve
in the gas
supply
line. Wait a few minutes
for
•
gas to move through
the gas line.
Fire Hazard
Do Not use an open flame to test for leaks
from gas connections.
Checking for leaks with a flame may result
in a fire or explosion.
Panel C
I12 I
Use a brush and liquid detergent
to test all gas connections for
•
leaks. Bubbles around
connections will indicate a leak. If
a leak appears, shut off gas valve controls and
adjust connections.
Then check connections
again. NEVER TEST FOR GAS LEAKS WITH
A MATCH OR OTHER FLAME. Clean all
detergent solution from cooktop.
j131
-
Plug the power
(r__K___
supply cord into
•
the grounded
outlet.
Place
14•
burner
grates over
burners and
caps. Install control knobs
on valve stems.
Electronic
Ignition
System-
initial lighting
Cooktop burners use electronic igniters in place
of standing pilots. When the cooktop control
knob is pushed in and turned to the "LITE"
position, the system creates a spark to light the
burner. This sparking continues until the control
knob is turned to the desired setting.
I1 5 ] O'ec"'"e
°
"J
O0
operation
oo
•
of the
cooktop
burners. Push in and
_,_ IN
turn each control knob
to "LITE" position. The flame should light within 4
seconds. Do Not leave the knob in the "LITE"
position
after burner lights.
If burners do not light properly, turn control knob
to the "OFF" position. Check that burner cap is in
the proper position. Check that power supply
cord is plugged in and that circuit breaker or
house fuse has not blown. Check that the shutoff
valve is in the "ON" position. Check operation
again. If a burner does not light at this point,
contact your KitchenAid dealer for assistance.
6
Check each cooktop
burner for proper flame.
•
The small inner cone
should have a very
distinct blue flame approximately
1/2"
(1.3cm) long. The outer cone is not as
distinct as the inner cone.
I17 I
Push in and turn each control knob
to the "LO" (or simmer) setting. The
•
"LO" setting of each burner has
been factory set to the lowest
setting available to provide reliable reignition of the
burner. If it does not stay lit on the "LO" setting,
check "LO" setting as follows:
a. Turn control to "LITE" until burner ignites.
b. Quickly turn knob down to LOWEST POSITION.
c. If burner goes out, readjust valve as follows:
Remove the surface burner control knob. Insert a
flat-blade screwdriver into the hollow valve stem
and engage the slotted screw inside. Flame size
can be increased or decreased with the turn of the
screw. Adjust flame until you can quickly turn knob
from "LITE" to LOWEST POSITION without
extinguishing the flame. Flame should be as small
as possible without going out.
To get the most efficient
use
from your new cooktop,
read
your KitchenAid
Use and Care
Guide.
Keep Installation
Instructions
and Guide close
to cooktop
for easy reference.
L.P, gas conversion
No attempt shall be made to convert the
appliance from the gas specified on the
model/serial rating plate for use with a different
gas without consulting the servicing gas supplier.
Conversion
must be done by a service
technician. Conversion Kit No. 4173627 is
available from your KitchenAid dealer or
authorized parts distributor.