Avantco 178SSUD3R Gebruikershandleiding - Pagina 9

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Avantco 178SSUD3R. Avantco 178SSUD3R 10 pagina's.

Avantco 178SSUD3R Gebruikershandleiding

Troubleshooting

Compressor Not Running
Fuse blown or circuit breaker tripped.
Power cord unplugged.
Thermostat set too high.
Cabinet in defrost cycle.
Condensing Units Run For Long Periods of Time.
Excessive amount of warm product placed in cabinet.
Prolonged door opening or door ajar.
Door gasket(s) not sealing properly.
Dirty condenser coil.
Evaporator coil iced over.
Cabinet Temperature is too Warm.
Thermostat set too warm.
Airflow blocked.
Excessive amount of warm product placed in cabinet.
Fuse blown or circuit breaker tripped.
Dirty condenser coil.
Evaporator coil iced over.
User Manual
Replace fuse or reset circuit breaker.
Plug in power cord.
Set thermostat to lower temperature.
Wait for defrost cycle to finish.
Allow adequate time for product to cool down.
Ensure doors are closed when not in use. Avoid
opening doors for long periods of time.
Ensure gaskets are snapped in completely. Remove
gasket and wash with soap and water. Check condition
of gasket and replace if necessary.
Clean the condenser coil.
Unplug unit and allow coil to defrost. Make sure
thermostat is not set too cold. Ensure that door
gasket(s) are sealing properly.
Set thermostat to lower temperature.
Re-arrange product to allow for proper air flow.
Make sure there is at least four inches of clearance
from evaporator.
Allow adequate time for product to cool down.
Replace fuse or reset circuit breaker.
Clean the condenser coil.
Ensure doors are closed when not in use. Avoid
opening doors for long periods of time.
- 9 -