User Manual
Back Bar Refrigerators
Troubleshooting
Problem
Possible Solution
Fuse blown or circuit breaker tripped
Replace fuse or reset circuit breaker
Power cord unplugged
Plug in power cord
Compressor is
Not Running
Thermostat set too high
Set thermostat to lower temperature
Cabinet in defrost cycle
Wait for defrost cycle to finish
Thermostat is set too high
Set thermostat to lower temperature
Airflow is blocked
Re-arrange products to allow for proper airflow
Make sure there is at least four inches of clearance from the evaporator
Excessive amount of warm product placed in cabinet
Allow adequate time for product to cool down
Cabinet Temperature
is too Warm
Fuse blown or circuit breaker tripped
Replace fuse or reset circuit breaker
Low refrigerant levels
Clean the condenser coil
Prolonged door opening or door ajar
Ensure doors are closed when not in use
Avoid opening doors for long periods of time
Excessive amount of warm product placed in cabinet
Allow adequate time for product to cool down
Prolonged door opening or door ajar
Ensure doors are closed when not in use
Avoid opening doors for long periods of time
Door gasket(s) not sealing properly
Condensing Units Run
Ensure gaskets are snapped in completely
for Long Periods of Time
Remove gasket and replace if necessary
Dirty condenser coil
Clean the condenser coil
Evaporator coil iced over
Unplug unit and allow coil to defrost
Make sure thermostat is not set too cold
Ensure that door gasket(s) are sealing properly
www.AvantcoRefrigeration.com