2. Error Signal Check And Solutions
2.1.
Error message
communication over 90 seconds, check communication wire first, if the wire is ok, try replacing the
console or generator controller.
2.2.
Error message
peddling and wait for the console power off then start peddling to power up the console. If still
showing error message, replace the generator controller.
2.3.
Error message
3 seconds), may be caused by the user peddling too fast. Normal peddling rpm range shall be
under 180 rpm. Stop peddling and wait for the console power off then start peddling to power up
the console. If still showing error message, replace the generator controller.
2.4.
Error message
1 seconds), may be caused by the user peddling too fast. Normal peddling rpm range shall be
under 180 rpm. Stop peddling and wait for the console power off then start peddling to power up
the console. If still showing error message, replace the generator controller.
2.5.
Error message
peddling and wait for the console power off then start peddling to power up the console. If still
showing error message, replace the generator controller.
2.6.
Error message
seconds. Stop peddling and wait for the console power off then start peddling to power up the
console. If still showing error message, replace the generator controller.
2.7.
Error message
seconds. Stop peddling and wait for the console power to off then start peddling to power up the
console. If still showing error message, replace the generator controller.
2.8.
Error message
Replace the generator controller.
2.9.
Error message
coil did not connect to the controller (CN6-refer to 1.3). Check the coil connection or the replace
controller.
www.GreenSeriesFitness.com
『
C OMMUNICATION FAIL
D C BUS ERROR
『
』 :
D CV VOLT OVERLOAD
『
D CV VOLT OVERVOLT
『
M V VOLT OVERLOAD
『
C MP CURR OVERLOAD
『
C MP CURR OVERCURR
『
S HORT CIRCUIT
『
』 :
C URRENT STATE NG
『
©May 2015
CIR-EL7000-G, CIR-RB7000-G, CIR-UB7000-G Revision 1.1
』 :
C onsole and generator controller did not
T he generator AC power cannot convert to DC power. Stop
G enerator controller DC voltage too high (over 300V-
』 :
G enerator controller DC voltage too high (over 350V-
』 :
G enerator controller output voltage overload. Stop
』 :
G enerator controller output current over 3A- 3
』 :
G enerator controller output current over 3.5A- 1
』 :
G enerator controller output component short circuit.
G enerator controller output circuit is abnormal or the
』 :
Call Toll free (800) 269-7140